View Cart (0)

Vesco Medical Pediatric Nasogastric Feeding Tube with ENFit Connector 6 Fr. 24 Inch Tube Polyurethane Sterile

Price is viewable only to staff.
Our price:  
Save when you order or more!

Minimum quantity: Limit per customer

Read more.

We're sorry, this item is out of stock. We're sorry, this item is currently unavailable. Get notified
Free Shipping!
In Stock
Rx Required

Pediatric Nasogastric Feeding Tube with ENFit Connector 6 Fr. 24 Inch Tube Polyurethane Sterile

This pediatric nasogastric feeding tube is a sterile 6 Fr. tube with an ENFit connector for enteral feeding, flushing, and medication administration. It fits pediatric care settings where buyers need a tube that supports visibility, placement confirmation, and consistent flow management. The 24 inch polyurethane tube is clear and transparent, radiopaque for x-ray confirmation, and marked in centimeters for measurement during placement and monitoring.

Good Fit For

  • Pediatric enteral feeding workflows
  • Care settings that use ENFit connections
  • Longer-term tube use up to 30 days
  • Situations where x-ray placement confirmation is needed

Key Features

  • ENFit port supports feeding, flushing, and medication administration through one connection
  • Clear, transparent tube helps clinicians monitor fluid content
  • Kink resistant polyurethane tubing supports dependable handling during use
  • Two side ports help improve flow and reduce the likelihood of clogging
  • Radiopaque construction allows x-ray confirmation of tube placement
  • Centimeter graduated markings help with placement measurement and ongoing checks

Applications and Usage

  • Enteral feeding for pediatric patients
  • Flushing the tube through the ENFit port
  • Administering medication through the same ENFit connection
  • Monitoring fluid content in a clear tube during care
  • Confirming tube placement by x-ray

Packaging and Handling

  • Packaging: EA.
  • Size: 24 Inch.
  • Sterility: Sterile.
  • This tube is indicated for long term use up to 30 days.
  • The device is sterilized and should not be re-sterilized.
  • Buyers using enteral systems should confirm their workflow uses an ENFit connection.
  • The tube size is 6 Fr. with a 24 inch length, so selection should match patient and protocol requirements.

FAQ

  • Does this feeding tube use an ENFit connection? Yes. This pediatric nasogastric feeding tube has a single ENFit port for feeding, flushing, and administering medication.
  • Can clinicians confirm placement by x-ray? Yes. The tube is radiopaque, which supports x-ray confirmation of tube placement.
  • How does this tube help with flow and clog reduction? The tube has two side ports that improve flow and help reduce the likelihood of clogging.
  • Is the tube marked for measurement during placement? Yes. The tube has centimeter graduated length markings to help with measurement and monitoring.
  • How long is this tube intended to be used? This pediatric nasogastric feeding tube is indicated for long term use up to 30 days.

From Vesco Medical.

  • Quantity : 1 Each
  • Application : Pediatric Nasogastric Feeding Tube with ENFit® Connector
  • HCPCS : B4081
  • Material : Polyurethane
  • Sterility : Sterile
  • Tube Size : 6 Fr.
  • Tubing Length : 24"
  • UNSPSC Code : 42231700

Prescription Information

A valid medical prescription must be submitted to Betty Mills within seven (7) days for the ordered item(s), and shipping will be on hold until the prescription is received. If the prescription is not provided within this timeframe, the order may be canceled. This requirement does not apply to licensed care providers, training facilities, equivalent qualified professionals, or licensed wholesalers, who are exempt from this policy.

Prescriptions may be sent via:

Fax
(650) 443-5201
Mail
The Betty Mills Company, Inc.
19 South B Street Suite 8
San Mateo, CA 94401

You are entitled to a free consultation following the purchase of this item.

Sizing Chart

Product Documents