Heat and Moisture Exchanger Thermovent T2 25mg 1-1 H2O at 15 Breath/min-1 500 ml

The Thermovent T2 heat and moisture exchanger helps support airway moisture and heat exchange in breathing circuits. Buyers may choose it when they want quick suction catheter access, oxygen port integration, and clear visual monitoring in patient care settings. This version uses paper media, has 11 mL dead space, and is rated for 500 mL tidal volume.

Good Fit For

  • Airway care setups needing suction catheter access
  • Breathing circuits where visual contamination checks are helpful
  • Patient care workflows using supplemental oxygen connection

Key Features

  • Simple opening port allows quick access for a suction catheter to help remove secretions
  • Clear housing supports visual checks for contamination during use
  • Integrated oxygen port can provide up to 60% oxygen concentration through a simple connection
  • Paper media supports heat and moisture exchange performance
  • Smooth, rounded edges help promote patient comfort
  • 11 mL dead space and 500 mL tidal volume help buyers match the unit to workflow needs

Applications and Usage

  • Supporting heat and moisture exchange in a breathing circuit
  • Allowing quick suction catheter access for secretion removal
  • Adding oxygen through the integrated oxygen port
  • Visually checking the housing for contamination during use

Packaging and Handling

  • Packaging: EA.
  • Material: Paper.
  • Check that the 500 mL tidal volume aligns with your intended application
  • Review the dead space and resistance values when comparing airway components
  • If oxygen delivery is part of the setup, confirm the integrated oxygen port fits your workflow

FAQ

  • Does this heat and moisture exchanger allow suction catheter access? Yes. The Thermovent T2 has a simple opening port for quick and easy access with a suction catheter to aid secretion removal.
  • Can this unit be used with oxygen? Yes. The integrated oxygen port can provide up to 60% oxygen concentration through a simple connection.
  • Is the housing clear? Yes. The clear housing helps with visualisation of contamination during use.
  • What tidal volume is this model rated for? This Thermovent T2 model is rated for 500 mL tidal volume.
  • What is the dead space for this exchanger? The dead space is 11 mL.

From Thermovent T2 by Smiths Medical.

  • Quantity : 1 Each
  • Application : Heat and Moisture Exchanger
  • Dead Space : 11 mL
  • Moisture Output : 25mg 1-1 H2O at 15 Breath/min-1
  • Resistance : 0.3 hPa (cmH2O) at Gas Flow Rate 0.5l/sec-1, 0.7 hPa (cmH2O) at Gas Flow Rate 1.0l/sec-1, 1.2 hPa (cmH2O) at Gas Flow Rate 1.5l/sec-1
  • Tidal Volume : 500 mL
  • UNSPSC Code : 42272219

Prescription Information

A valid medical prescription must be submitted to Betty Mills within seven (7) days for the ordered item(s), and shipping will be on hold until the prescription is received. If the prescription is not provided within this timeframe, the order may be canceled. This requirement does not apply to licensed care providers, training facilities, equivalent qualified professionals, or licensed wholesalers, who are exempt from this policy.

Prescriptions may be sent via:

Fax
(650) 443-5201
Mail
The Betty Mills Company, Inc.
19 South B Street Suite 8
San Mateo, CA 94401

You are entitled to a free consultation following the purchase of this item.

Sizing Chart

Product Documents

SAM.gov