In Stock
Rx Required

Heat and Moisture Exchanger 30 mg at 34 degree C for 500 mL Tidal Volume, 27 mg at 34 degree C for 1000 mL Tidal Volume 1 hPa at .5 L per Second, 3 hPa at 1 L per Second, 5 hPa at 1.5 L per Second, 20 EA/CS

This heat and moisture exchanger with flex tube helps provide passive humidification between the patient and circuit. It may be a fit for anesthesia or ICU settings where buyers want easier connection to an endotracheal tube. The unit uses treated open-cell foam media and has 16 mm I.D. x 22 mm O.D. connection ports on the patient end with a 15 mm O.D. circuit end.

Good Fit For

  • Anesthesia settings
  • ICU respiratory care
  • Setups requiring easier connection to an endotracheal tube

Key Features

  • Passive humidification between patient and circuit for respiratory care workflows
  • Flex tube supports easier connection to an endotracheal tube
  • Suitable for anesthesia or ICU use
  • Treated open-cell foam media
  • Patient-end connection ports: 16 mm I.D. x 22 mm O.D.; circuit end: 15 mm O.D.
  • Dead space of 70 mL for buyers reviewing ventilation setup details

Applications and Usage

  • Passive humidification between a patient and breathing circuit
  • Anesthesia breathing circuit setups
  • ICU ventilation workflows involving an endotracheal tube

Packaging and Handling

  • Packaging: CS.
  • Size: 16 mm.
  • Material: Foam.
  • Sterility: Sterile.
  • Check connection port sizes against your patient-end and circuit-end requirements before ordering.
  • Review dead space and resistance values as part of ventilator circuit selection.
  • This item is non-sterile.

FAQ

  • Where can this heat and moisture exchanger be used? This heat and moisture exchanger can be used in anesthesia or ICU settings.
  • Does this model include a flex tube? Yes. This heat and moisture exchanger includes a flex tube for easier connection to an endotracheal tube.
  • What are the connection sizes? The patient end has 16 mm I.D. x 22 mm O.D. connection ports, and the circuit end is 15 mm O.D.
  • What media type does this heat and moisture exchanger use? It uses treated open-cell foam media.
  • What performance details are provided? Moisture output is 30 mg at 34 degree C for 500 mL tidal volume and 27 mg at 34 degree C for 1000 mL tidal volume. Resistance is 1 hPa at .5 L per second, 3 hPa at 1 L per second, and 5 hPa at 1.5 L per second.

From Smiths Medical.

  • Quantity : 20 per Case
  • Sterile : No
  • Connection Ports : 16 mm I.D. X 22 mm O.D. on patient end; 15 mm O.D. on circuit end
  • Moisture Output : 30 mg at 34 degree C for 500 mL Tidal Volume, 27 mg at 34 degree C for 1000 mL Tidal Volume
  • Application : Heat and Moisture Exchanger
  • Dead Space : 70 mL
  • Resistance : 1 hPa at .5 L per Second, 3 hPa at 1 L per Second, 5 hPa at 1.5 L per Second
  • Media Type : Treated Open-cell Foam
  • UNSPSC Code : 42272219

Prescription Information

A valid medical prescription must be submitted to Betty Mills within seven (7) days for the ordered item(s), and shipping will be on hold until the prescription is received. If the prescription is not provided within this timeframe, the order may be canceled. This requirement does not apply to licensed care providers, training facilities, equivalent qualified professionals, or licensed wholesalers, who are exempt from this policy.

Prescriptions may be sent via:

Fax
(650) 443-5201
Mail
The Betty Mills Company, Inc.
19 South B Street Suite 8
San Mateo, CA 94401

You are entitled to a free consultation following the purchase of this item.

Sizing Chart

Product Documents