View Cart (0)
bmPrintHeader

Proactive Medical Protekt Aire 8000BA-60

Price is viewable only to staff.
Our price:  
Save when you order or more!

Minimum quantity: Limit per customer

Read more.

We're sorry, this item is out of stock. We're sorry, this item is currently unavailable. Get notified
Free Shipping!
In Stock
Rx Required

Protekt Aire 8000BA-60

The Protekt Aire 8000BA-60 is an alternating pressure and low air loss mattress system for pressure redistribution and moisture management. It fits care settings that need adjustable support, transfer-friendly operation, and safeguards such as low pressure alarms and a CPR pull tab. Key details include customizable 10, 15, 20, and 25 minute pressure cycles, 18 liters per minute air flow, and a 660 lb weight capacity.

Good Fit For

  • Patient care settings that need pressure redistribution
  • Beds where easier transfers are important
  • Workflows that benefit from locked control settings
  • Care environments requiring quick deflation for CPR access

Key Features

  • Alternating pressure cycles at 10, 15, 20, and 25 minutes help clinicians customize pressure redistribution
  • Low air loss function manages moisture to help prevent skin maceration
  • Cell-on-cell mattress design helps prevent bottoming out during power failure
  • Static mode supports easier patient transfer in and out of bed
  • Audio and visual low pressure alarms alert clinicians when preset pressure levels decrease
  • 660 lb weight capacity with 18 liters per minute air flow for demanding care environments

Applications and Usage

  • Customizing alternating pressure cycle times based on patient needs
  • Managing moisture at the support surface with low air loss operation
  • Reducing bottoming out risk with seat inflate and cell-on-cell design
  • Locking settings to help prevent tampering with control panel adjustments
  • Quickly releasing air from the mattress during CPR response

Packaging and Handling

  • Packaging: EA.
  • Size: 60".
  • The lock out key locks the control panel, including the power switch
  • Static mode may be helpful when moving patients in or out of bed
  • Seat inflate increases air flow by 20% to the middle bladders
  • The pillow top is intended to reduce head and neck movement during alternating mode

FAQ

  • Can clinicians adjust the alternating pressure cycle time? Yes. The Protekt Aire 8000BA-60 offers alternating pressure cycles of 10, 15, 20, and 25 minutes so clinicians can tailor pressure redistribution.
  • Does this mattress help manage moisture? Yes. The low air loss function controls and manages moisture to help prevent skin maceration.
  • What happens if power fails? The cell-on-cell mattress design helps prevent the patient from bottoming out in case of power failure.
  • Is there a transfer mode? Yes. Static mode allows for easier transfer in and out of bed.
  • What weight capacity does this mattress support? The Protekt Aire 8000BA-60 has a 660 lb weight capacity.

From Protekt by Proactive Medical.

  • Quantity : 1 Each
  • Material : Nylon
  • Size : 60"x80"x8"

Prescription Information

A valid medical prescription must be submitted to Betty Mills within seven (7) days for the ordered item(s), and shipping will be on hold until the prescription is received. If the prescription is not provided within this timeframe, the order may be canceled. This requirement does not apply to licensed care providers, training facilities, equivalent qualified professionals, or licensed wholesalers, who are exempt from this policy.

Prescriptions may be sent via:

Fax
(650) 443-5201
Mail
The Betty Mills Company, Inc.
19 South B Street Suite 8
San Mateo, CA 94401

You are entitled to a free consultation following the purchase of this item.

Sizing Chart

Product Documents

SAM.gov