View Cart (0)
bmPrintHeader
Price is viewable only to staff.
Our price:  
Save when you order or more!

Minimum quantity: Limit per customer

Read more.

We're sorry, this item is out of stock. We're sorry, this item is currently unavailable. Get notified
Free Shipping!
In Stock
Rx Required

Immunoassay Reagent Alinity i 25-hydroxyvitamin D (25-OH Vitamin D) For Alinity i Analyzer 200 Tests, 1/EA

This immunoassay reagent is a 25-hydroxyvitamin D assay for use on the Alinity i analyzer. It fits laboratories and clinical testing settings that need quantitative testing of 25-OH vitamin D in human serum or plasma to aid assessment of vitamin D sufficiency. This cartridge-format assay uses chemiluminescent microparticle immunoassay methodology and supports up to 200 tests.

Good Fit For

  • Laboratories using the Alinity i analyzer
  • Vitamin D sufficiency assessment workflows
  • Serum and plasma testing applications

Key Features

  • 25-hydroxyvitamin D assay for quantitative determination of 25-OH vitamin D
  • Built for use with the Alinity i analyzer, helping buyers match the reagent to the correct instrument
  • Works with human serum and plasma samples for routine lab workflows
  • CMIA methodology supports immunoassay testing on the Alinity i platform
  • 200-test format helps support higher-volume purchasing and planning
  • Requires refrigeration, an important consideration for storage and handling

Applications and Usage

  • Quantitative testing of 25-hydroxyvitamin D in human serum
  • Quantitative testing of 25-hydroxyvitamin D in human plasma
  • Laboratory workflows that use the Alinity i analyzer for bone metabolism testing
  • Nutritional assessment testing where 25-OH vitamin D results are needed

Packaging and Handling

  • Packaging: EA.
  • Confirm your site uses the Alinity i analyzer before ordering, since this reagent is platform-specific.
  • Refrigerated storage is required, so receiving and storage procedures should support cold-chain handling.
  • This assay is intended to aid the assessment of vitamin D sufficiency.

FAQ

  • Which analyzer is this reagent for? This immunoassay reagent is for use with the Alinity i analyzer.
  • What sample types does the assay use? The assay is used with human serum and plasma samples.
  • What does this test measure? This assay quantitatively determines 25-hydroxyvitamin D, also called 25-OH vitamin D.
  • How many tests does this reagent support? This SKU supports 200 tests.
  • Does this reagent need special storage? Yes. Refrigerated storage is required.

From Abbott Nutrition.

  • Quantity : 1 Each
  • Application : Immunoassay Reagent
  • For Use With : For Alinity i Analyzer
  • Number of Tests : 200 Tests
  • Product Dating : McKesson Acceptable Dating: we will ship >= 60 days
  • Sample Type : Serum / Plasma Sample
  • Specialty : Immunoassay
  • Storage Requirements : Requires Refrigeration
  • Test Category : Bone Metabolism
  • Test Format : Cartridge
  • Test Method : Chemiluminescent Microparticle Immunoassay (CMIA)
  • Test Name : 25-hydroxyvitamin D (25-OH Vitamin D)
  • Test Type : Nutritional Assessment
  • Volume : R1: 6.6 mL, R2: 6.1 mL, Diluent: 10.4 mL

Prescription Information

A valid medical prescription must be submitted to Betty Mills within seven (7) days for the ordered item(s), and shipping will be on hold until the prescription is received. If the prescription is not provided within this timeframe, the order may be canceled. This requirement does not apply to licensed care providers, training facilities, equivalent qualified professionals, or licensed wholesalers, who are exempt from this policy.

Prescriptions may be sent via:

Fax
(650) 443-5201
Mail
The Betty Mills Company, Inc.
19 South B Street Suite 8
San Mateo, CA 94401

You are entitled to a free consultation following the purchase of this item.

Sizing Chart

Product Documents

SAM.gov