Vitalograph Medical Spirometer Bacterial/Viral Filter 2820 Series BVF, 50/BX
Spirometer Bacterial/Viral Filter 2820 Series BVF, 50/BX
This spirometer bacterial/viral filter is for inspiratory and expiratory spirometry testing. It fits buyers who want to help protect both the subject and the spirometer from cross-infection and cross-contamination during testing. Key details include 99.99% cross-contamination efficiency, very low expiratory flow impedance, and 65 mL effective dead space.
Good Fit For
- Spirometry testing with inspiratory and expiratory measurements
- Lung volume and DLCO testing workflows
- Settings focused on reducing cross-contamination between subject and spirometer
Key Features
- Made for inspiratory and expiratory spirometry testing
- Helps protect the subject against cross-infection during testing
- Helps protect the spirometer against cross-contamination
- 99.99% cross-contamination efficiency for high-filtration performance
- Very low expiratory flow impedance to support testing workflow
- 65 mL effective dead space, noted for lung volume and DLCO testing
Applications and Usage
- Adding a bacterial/viral filter to routine spirometry testing
- Supporting inspiratory and expiratory spirometry procedures
- Using a low-dead-space filter for lung volume testing
- Using a filter during DLCO testing
- Reducing cross-contamination risk during spirometer use
Packaging and Handling
- Packaging: BX.
- This filter is intended for use with spirometers.
- Buyers comparing airflow performance may want to note the stated low expiratory flow impedance and airflow resistance values at 750 L/min.
- For testing protocols where dead space matters, this model has 65 mL effective dead space.
FAQ
- Can this filter be used for both inspiratory and expiratory spirometry testing? Yes. This spirometer bacterial/viral filter is suitable for both inspiratory and expiratory spirometry testing.
- What does this filter help protect against during spirometry? The filter is intended to help protect the subject against cross-infection and the spirometer against cross-contamination.
- Is this filter appropriate for lung volume and DLCO testing? Yes. The product details note a low effective dead space of 65 mL as required for lung volume and DLCO testing.
- How efficient is the filtration performance? The product details state 99.99% cross-contamination efficiency and 99.99% efficiency at 55 and 750 L/min.
- Does the filter support high flow rate testing? Yes. The product details say the filter is efficient at high flow rates and has very low expiratory flow impedance.
From 2820 Series BVF by Vitalograph Medical.
- Quantity : 50 per Box
- Application : Spirometer Bacterial/Viral Filter
- For Use With : For Spirometers
- Specifications : Green, Electrostatic Nanofibre Technology Filter Medium, 65 mL Effective Deadspace
Prescription Information
A valid medical prescription must be submitted to Betty Mills within seven (7) days for the ordered item(s), and shipping will be on hold until the prescription is received. If the prescription is not provided within this timeframe, the order may be canceled. This requirement does not apply to licensed care providers, training facilities, equivalent qualified professionals, or licensed wholesalers, who are exempt from this policy.
Prescriptions may be sent via:
19 South B Street Suite 8
San Mateo, CA 94401
You are entitled to a free consultation following the purchase of this item.
Sizing Chart
Product Documents
Respiratory Top Sellers
-
Replacement Filters for Protekt Nebulizer (PTC PMNEB-FLT)
$1.04 Per Pack -
5-in-1 Tubing Connector (IND 55360-BX)
$59.92 Per Box
Customers also Viewed
-
Irrigation Solution (37-6260), 24 EA/CS (MON 520119CS)
$52.72 Per Case
This weeks Deals
-
Scott® Essential C-Fold Towels (KCC 01510)
$57.88 Per Carton -
GEN Standard Bath Tissue (GEN 218)
$69.88 Per Carton -
Boardwalk Scrubbing Sponge (BWK 174)
$18.88 Per Carton